5.1.1.5. qRT-PCR program

Set program as follows:

  • 50°C, 2 min, 1 cycle
  •  95°C, 2 min, 1 cycle
  •  95°C, 20 sec, 40 cycles
  •  60°C, 40 sec, 40 cycles